Drolet Savannah II Wood Stove DB03028
Heating area |
500 - 1,800 Ft2
|
Size |
24 7/8" W X 23 5/8" D X 30 5/8" H |
Maximum log length |
18" |
Average particulate emissions rate (1)
|
1.26 g/h |
FEATURES:
Of medium size, the Savannah II wood stove is ideal for heating spaces up to 1,800 ft². With a maximum heat output of 65,000 BTU/h, this EPA certified at 1.26 g/h non-catalytic unit represents an eco-responsible heating source. The standard air deflector on the Savannah II will boost air movement through the room.
Included: pedestal with ash drawer, air deflector, ceramic glass, ash lip, air damper
- Up to 6 hours burn time
- Up to 18'' logs
- 1.9 ft³ firebox
- Heavy duty 5/16'' steel top
- EPA certified
- Proudly made in Canada
- Limited lifetime warranty
- Certified for mobile home and alcove installation
Options: blower, thermodisc, firescreen, fresh air intake kit
Savannah II stove install & owner's manual
(PDF - 6.1 Mo)
Savannah II stove dimensions
(PDF - 0.4 Mo)
Government incentives may apply to this product.
LEARN MORE
*Any installation must be done according to the data and drawings detailed in the owner’s manual.
SPECIFICATIONS:
Fuel type |
Dry cordwood (16" recommended) |
Recommended heating area-ft² ()
|
500 - 1,800 |
Overall firebox volume-ft³ |
1.9 |
EPA loading volume-ft³ |
1.44 |
Maximum burn time ()
|
6 h |
Maximum heat output-dry cordwood (3)
|
65,000 BTU/h (19 kW) |
Overall heat output rate < (3) (4)
|
15,650 BTU/h (4.6 kW) to 23,300 BTU/h (6.83 kW)
|
Average overall efficiency (dry cordwood) (4)
|
70 % (HHV) (5)
|
75 % (LHV) (6)
|
Optimum overall efficiency (7) (8)
|
78 % |
Optimum heat transfer efficiency (9)
|
74 % |
Average particulate emissions rate (1)
|
1.26 g/h |
Average CO (10)
|
58 g/h |
(1) This appliance is officially tested and certified by an independent agency.
(2) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(3) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(4) As measured per CSA B415.1-10 stack loss method.
(5) Higher Heating Value of the fuel.
(6) Lower Heating Value of the fuel.
(7) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
(8) Optimum overall efficiency at a specific burn rate (LHV).
(9) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
(10) Carbon monoxyde.
General Features:
Combustion technology |
Non-catalytic |
High-efficiency certified appliance |
Yes, EPA 2020 approved |
Maximum log length |
18" |
Log positioning |
Loading over width |
Chimney diameter |
6" |
Flue outlet diameter |
6" |
Type of chimney |
CAN/ULC S629, UL 103 HT (2100 °F) |
Minimum chimney height (feet) |
12' |
Baffle type |
High quality vermiculite |
Approved for an alcove installation |
Yes |
Approved for a mobile home installation |
Yes, with fresh air intake |
Shipping Weight |
314 lb (142 kg) |
Door type |
Single, glass with cast iron frame |
Glass type |
Ceramic glass |
Glass surface – dimensions (Width X Height) |
15 3/4" x 9 3/4" |
Glass air-wash system |
Yes |
Overall dimension (Height) |
30 5/8" |
Overall dimension (Width) |
24 7/8" |
Overall dimension (Depth) |
23 5/8" |
Door opening – dimension (Height) |
8" |
Door opening - dimension (Width) |
17 1/4" |
Firebox – dimension (Height) |
11 7/8" |
Firebox – dimension (Width) |
19 5/8" |
Firebox – dimension (Depth) |
13 1/2" |
Firebox lined with refractory bricks for better heat distribution |
Yes |
Stainless-steel secondary-air system improving gas combustion |
Yes |
Model |
Pedestal |
Steel thickness – body |
3/16" |
Steel thickness – top |
5/16" |
USA standard (emissions) |
EPA |
Canadian Standard (emissions) |
CSA B415.1-10 |
USA standard (safety) |
UL 1482, UL 737 |
Canadian standard (safety) |
ULC S627 |
Tested and listed as per applicable standards |
By an accredited laboratory (CAN/USA) |
Warranty |
Limited lifetime |
Minimum clearances to combustibles* (Data expressed in inches. 1 inch = 25.4 mm)
|
|
Canada |
United-States |
|
Single wall pipe |
Double wall pipe |
Single wall pipe |
Double wall pipe |
Clearance – back wall |
14 1/2" |
7 1/2" |
13" |
7 1/2" |
Clearance - corner |
12" |
12" |
12" |
12" |
Clearance – side wall |
16" |
16" |
15" |
15" |
Clearance – top (measured from the platform on which the appliance is installed)** |
84" |
84" |
84" |
84" |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
|
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
|